 TITLE:
What is the initial timer period about EM57000 series
REVISED DATE REVISED VERSION APPLY TO CHIPS APPLY TO SOFTWARE : : : : 14, JUNE, 1998 1.0 EM57000 Series Chip ALL EM57000 series coding system above version 2.1
SEE ALSO: 1. The timer in EM57000 series can be adjusted whenever it is required. The available timer period is :
1 mS, 8 ms, 32 ms and 64 mS.
2. The initial timer period will be set as 8 ms when power on. 3. To change timer period by program, use following commands :
MOV TIMER #TDATA
TDATA can be 0 to 3 as following shown :
MOV MOV MOV MOV
TIMER TIMER TIMER TIMER
#0 #1 #2 #3
; ; ; ;
Set Set Set Set
as as as as
1 8 32 64
ms ms ms ms
as as as as
timer timer timer timer
period period period period